Performance monitoring of heat exchangers via adaptive observers
CARLOS MANUEL ASTORGA ZARAGOZA
Arturo Zavala Río
VICTOR MANUEL ALVARADO MARTINEZ
JUAN REYES REYES
Acceso Abierto
Atribución-NoComercial-SinDerivadas
https://doi.org/10.1016/j.measurement.2006.06.009
Performance monitoring
Heat exchanger
Adaptive observer
"In this paper, a method for monitoring the performance degradation in a heat exchanger is presented. This method is based on the use of an adaptive observer which estimates the overall heat transfer coefficient U. The monitoring of this parameter can be useful to decide when the heat exchanger needs preventive or corrective maintenance. A simplified mathematical model of the heat exchanger is used to synthesize the adaptive observer. The effectiveness of the proposed method is demonstrated via numerical simulations and through experimental results."
Elsevier
2007
Artículo
C.-M. Astorga-Zaragoza, A. Zavala-Río, V.M. Alvarado, R.-M. Méndez, J. Reyes-Reyes, Performance monitoring of heat exchangers via adaptive observers, Measurement, Volume 40, Issue 4, 2007, Pages 392-405.